Glove box + anaerobic anhydrous molten salt plating furnace

Release time: 2024-07-10 03:41:12 Number of views: 126

01 (1)

Equipment introduction:

The glove box is a laboratory device that fills the box with high purity inert gases and circulates to filter out the active substances. Also known as vacuum glove box, inert gas protection box, etc.

The main function is the elimination of O₂, H₂O, organic gas. Widely used in water-free, oxygen-free, dust-free ultra-pure environment, such as: lithium ion batteries and materials, semiconductors, supercapacitors, special lamps, laser welding, brazing, material synthesis, OLED, MOCVD, etc. It also includes biological applications, such as anaerobic bacteria culture, cell hypoxic culture, et

Edit Content

Suitable for: colleges and universities, scientific research institutions, battery material production and battery production enterprises on button battery, analogue battery, half battery, three electrode battery, supercapacitor and other related electrochemical aspects of the research and testing.

Test items: detailed data of charge and discharge, cycle life, charge and discharge curves, charge and discharge efficiency, specific capacity, specific energy, DC resistance, leakage (self-discharge) current and other items.

Edit Content

Glove box + anaerobic anhydrous molten salt plating furnace

Release time: 2021-05-09 08:28:22  Number of views: 927

Equipment introduction:

The glove box is a laboratory device that fills the box with high purity inert gases and circulates to filter out the active substances. Also known as vacuum glove box, inert gas protection box, etc.

The main function is the elimination of O₂, H₂O, organic gas. Widely used in water-free, oxygen-free, dust-free ultra-pure environment, such as: lithium ion batteries and materials, semiconductors, supercapacitors, special lamps, laser welding, brazing, material synthesis, OLED, MOCVD, etc. It also includes biological applications, such as anaerobic bacteria culture, cell hypoxic culture, etc

ProductBrief

ProductDetails

ProductVideo

MessageInquiry

Configuration details (glove box + series products)

Equipment characteristics:

1. Simple: user-friendly design operation window,
2. Intelligent HMI man-machine interface, easy to operate;
3. Safety: high sealing fully protects the safety of human body and samples;
4. High efficiency: integrated design improves equipment use efficiency; Energy saving: frequency conversion control operation.
5. Heating, pressure and other heat treatment equipment can be modified according to customer requirements.

Major component
1. Main box
2. Purification system
3. Solvent system
4. Water cooling
5. Large transition cabin
6. Small transition cabin
7. Control system

Control system
1. Cycle cycle: start and stop cycle purification system;
2. True empty pump: start and stop vacuum pump;
3 lighting: open, take care of the lamp;
4. Analyzer: control water oxygen analyzer;
5. Cleaning: Set details of cleaning parameters;
6. Tacit value: restore the default value set by the system;
7. Alarm setting: set water oxygen alarm prompt;
8. Settings: alarm Settings and leak detection Settings of the box, switch between Chinese and English;
9. Regeneration: press the regeneration key to control the purification column for regeneration;
10. Time setting: preset touch screen display time;
11. Record: query system operation record and water oxygen content record;

Transition cabin construction
1. Support frame; 2. Support rod; 3. Large hatch cover; 4. Large cabin shaft;
5. Large transition beam; 6. Handle; 7. Lead screw 8. Hook;
9. Vacuum pressure gauge;
10. Small hatch door;
11. Small hatch handle
12. Three-way ball valve;

Replacement of activated carbon

① vacuum gauge; ② three-way ball valve; (3) feeding port; (4) discharge port;
Specific replacement process:
1. Close the two butterfly valves on the solvent column (butterfly valve ② and butterfly valve ③ in 10.2);
2. Check whether ① (vacuum gauge) is under normal pressure. If it is under vacuum state, supplement air to normal pressure through ② (three-way ball valve)
3. Open ③ (feeding port) and ④ (discharging port);
4. Activated carbon flows out from ④ (discharge port); Tighten the clamp after cleaning;
5. Pour clean and dry activated carbon from ③ (feeding port); After installation, tighten the clamp;
6. Through the operation of ② (three-way ball valve), vacuum the solvent column and replenish air for three times.
7. Repeat 5.11.2 to flow the circulating gas through the solvent column.

Electrical specification

AC220V   6KW*2

Preparation and inspection before use

1. Prepare sufficient high purity working gas (please refer to Table 1 for gas specifications)
2. Prepare two 40L cylinders of recycled gas (gas specifications refer to Table 2 below)
3. Second pair of decompression table (one is used normally, the other is used again)

use

Clean the box, balance the pressure and work gas

Gas type

Nitrogen, argon or helium

purity

99.999% H2O ≤5ppm; O2 ≤5ppm or better

quantity

Meet the requirements of the equipment

Demand pressure

0.4-0.6MPa

Pressure gauge range

Main surface pressure range >15MPa; Sub-surface pressure range ≤ 1MPa

Connecting pipe

Material: Plastic; External diameter: ¢10mm; Inside diameter: ¢6.5mm;

Table 1 High purity working gas

use

Reduction purification column purification capacity

Gas type

When nitrogen is used as the working gas, nitrogen/hydrogen mixture (90-95% N2, 5-10% H2) is used;
When argon is used as the working gas, argon/hydrogen mixture (90-95% Ar, 5-10% H2) is used;
When helium is the working gas, use a helium/hydrogen mixture (90-95% He, 5-10%H2).

purity

99.999%  H2O ≤5ppm;  O2 ≤5ppm Or better

quantity

Each column requires 3500L or close to 40L cylinders of 10MPa gas pressure

Demand pressure

约 0.01-0.03MPa

Pressure gauge range

Main surface pressure range >10MPa; Sub-surface pressure range < 0.5MPa

Connecting pipe

Material: Plastic; External diameter: ¢10mm; Inside diameter: ¢6.5mm;

Table 2 Regenerated gas

Operation precautions

1. Personnel shall not use the glove box without training;
2. Prohibit the use of materials that can poison the regeneration catalyst, such as: sulfhydryl compounds, etc.
3. Do not use volatile solvents that will damage plexiglass, such as acetone, without permission;
4. Before using volatile solvent, contact the person in charge to unload the water probe;
5. Open the activated carbon circulation system when using volatile solvent;
6. When using the glove box, do not have long nails, do not wear sharp objects (such as watches, jewelry, etc.);

Disclaimer:

The product introduction content of this site (including product pictures, product descriptions, technical parameters, etc.) is for reference only. There may be some difference between the stated content and the actual situation due to the delay in updating. Please contact our customer service staff for confirmation. The information provided by this Site does not constitute any offer or acceptance. Nobardi will improve and modify any information on this site from time to time without prior notice.

Edit Content
Click on the Edit Content button to edit/add the content.
Edit Content
Click on the Edit Content button to edit/add the content.

推荐产品

Light duty melting furnace

Production vacuum atmosphere pendulum rotary sintering furnace 1200℃

Glove box plus high temperature furnace, etc

Ion sputtering coating instrument